hayward blue essence troubleshooting

Just opened up the pool and the Hayward Super Pump worked just fine until we started vacuuming the bottom. The click I was speaking of is definitely in the motor, not the outlet, although I realize they are right next to each other. in the filter. Washed out the 4 Large cartridge filters before startup. Fourth, check the motor shaft to be sure that it spins easily by hand, fifth, you can check the capacitor (for capacitance), if the motor still isnt starting. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell. No power not even a humming. Spray off well, and soak in a 5-gal bucket, the entire Flex Tube Nest, for a number of hours, hose off again, soak for another few hours, hose off thoroughly, dunk in the pool a few times, then replace in the filter tank. All works good now. I call that surging and its commonly caused by an air leak around the pump, either a loose pump lid, bad o-ring or loose drain plug or loose pipe coming into the pump. IF thats good, check the pipe coming into the pump, does it drip when the pump is off? that would be rare, very rare. With the information explained in this comprehensive troubleshooting guide, you can diagnose and repair your Hayward single speed or variable speed pool pump with ease! and check each motor lead to ground. When I turned off the pump I saw that it spit a little bit of water out of a Jandy Valve. The pump should really be on its own breaker if possible. Any ideas on troubleshooting this issue? If youre reading this blog that means you need help troubleshooting your Hayward Aqua Rite salt system. Checked the connection, which seems fine. The shaft is accessed in the rear of the motor, behind the centrifugal switch. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' The Inspect Cell LED (only) flashes or stays on when: The Check Salt & Inspect Cell LEDs flash together when: The Check Salt & Inspect Cell LEDs will stay ON when: Step 1: Check your system to confirm that you have programmed the correct cell size. 1. Now when we try to turn everything on the pump wont start at all and keeps tripping the breaker. just replaced t15 on a rev 1.45 aqua rite and the default salt reading now is 4. Hi Carlos, Im not familiar with working on those timers, a built-in to the back cover for Power-Flo pumps. If the shaft does spin fine, and is not locked up, you can try a new capacitor, or check your current cap, with an ohmmeter. hayward blue essence troubleshootingsolar panel for arlo essential spotlight camera hayward blue essence troubleshooting Menu everydrop water filter comparison. "url": "https://intheswim.com/",
If it clogs up again, you will need to break it down and manual clean, then soak in DE Filter Cleaner not so hard and the best cleaning, just a lot of little nuts and washers to remove and replace. If regular loudness, its likely an air leak. Copyright 2022 In The Swim. For over 2 months, lots of troubleshooting, actually RE-PIPED THE SECTION FROM POOL TO PUMP done by professionalpump still will not primedraws water, wont primeplayed with outflow and values, no primetook apart (my nemesis) Hayward Perflex DE filter, cleaned fingers, silicone on gaskets, put back (I have done this crappy job a hundred times so I am familiar with the process)no primefeel like draining the damn pool and junking the whole thing >:(. Hi John, sounds like a thermostat issue (or potentiometer for electronic heaters), although it could be another issue that just by coincidence happens when water is warm, like low flow rates. Then check the GFCI for loose wires. A large pair of channel type pliers can be placed on the impeller, over a cloth, and given some persuasion. Hello. Pool heaters can be the most baffling piece of pool equipment, but if you consider the proper flow of gas, water and electric, youre sure to find a solution quickly! Hi Tim, when the windings in a motor are shorted, the motor is pretty much dead, they arent rewound anymore, like in the old days. Big difference, but other than that, they operate pretty much the same! Your old motor may have been uprated, and new one full rated? You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. If your sweeper has a booster pump, could be a problem with a clogged impeller, or air leak into the pump, or some other pump issue. For the priming problem, you may have an air leak on the pump lid or around the pipe coming into the pump. For the leaking underneath, that sounds like the shaft seal SPX1600Z2 or it could be leaking around the plumbing fitting threads, where water exits the pump, and is running down the side of the pump and dripping off the bottom. Our switch seems to be getting power- a voltage tester confirms this but pump makes zero sound when switch is turned on. For either sand or DE, if you experience high pressure or poor filtration after backwashing or cleaning, try a Pool Filter Cleaner product to deep clean the filter. Seems impeller is not turning, does it turn both ways or one way? Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. I get home from work and the pump is running. Please consider. The help at the pool store had no idea what could be wrong. I inspected the impeller and it looks fine except where the threads are there are tiny hairline fractions. Would the lack of enough sand cause the water to gush out of the top of the filter? I would start by lubing the pump lid o-ring with pool lube, and trying to tighten the lid a bit more if you can. When the pool guy switched it, it worked very well for about a month with no issues at all. When I try to turn the pump back on, it only hums. Replace the seal in the same orientation as you removed it, and reassemble. "@type": "ImageObject",
Automatic restart is 2 minutes after the error condition is corrected and the limit string closes. FYI I moved the voltage selector to 115. Thanks. The Hayward swim profilter is making a loud noise and the top vibtrates. The selector plug MUST be moved or the breaker will trip every time you try to start it up. We live in Arizona, so the automatic freeze setting isnt an issue. K-1766 Taylor Salt Test Im thinking the new pump might be set for 230 and wiring is for 115. i hope this helps, but I am also maybe missing something. Just put he new motor on and its still not working, sounds like power is being sent to the motor, but nothing. What do you think? Specialties: Cycling, Kickboxing, The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. At first, the pump would only hum and not work. Is the GFCI test button tripped? Hi Davy, Try again? Any ideas as to what could be the problem? First inspect wiring, to be sure everything is tight and secure, and there are no loose wires, or anything that looks wrong back there. Also, DE filters need to be opened up and hosed down completely clean every 6-9 months, and then started up again with a full charge of DE powder. When pump start it work fine but after few hours water stop moving. IDXL2DB1930. The control is set for the wrong turbo cell type. Does it only do this when vacuuming, but otherwise runs fine? It is a common problem with Hayward Perflex, the symptoms you describe, and is usually clogged fingers. How Much Salt Belongs In Your Pool Pump had been working fine, but this week started making a kind of rhythmic buzzing sound while running. Or use this Pump Cord. I have a Hayward pump for my above ground pool, it is two years old. IF so, replace the fitting, or pack pool putty or silicone around the fitting, and leave it running for 24 hours, until the sealant sets up hard. The water level is good. I think you need two timers, usually, unless it can deliver 240 to the filter pump and 120 to the booster, at the same time. The error code will be cleared upon a valid data exchange between boards, If the limit string opens the heater shuts down and goes into lockout. Mark, if you can hear the motor winding up and down, then it could be the cord. Hi David, yes! No leaks, pressure is good, suction is good, connections seem right. It need not be a fancy $100 meter, it can be a $10 meter from Radio Shack. You can buy replacement drives I believe, that may be the (expensive) cure for the problem. I noticed the on/off switch seemed loose and when I took of the end case, the male disconnect to the switch was burned out. Hi Dave, check that the centrifugal switch is screwed on tightly to the end of the motor shaft. Use a flashlight, and you should see gears moving thru the small view hole. Possibly a bad breaker, they do wear out after 20 yrs or so. However it doesnt turn on. Reassemble pump in reverse order from above. The board wasnt showing anything. i cleaned the filter put the cover back on turned the pump but it doesnt seem to be priming . so.it shut off again. The outer walls become thin, allowing the pipe to crimp but only under high vacuum pressure, otherwise seems normal. 5. very dirty pool filter, Every time the pump is turned on with the timer it trips the circuit breaker. Hi Davy, my pump is on a timer and will occasionally fail to turn on in the morning. If it is a union valve, cream also on the union nut. Also, because of this leak, would It cause my pressure to decrease? What can be the cause? Go to the grocery store and come back and its dead. All pipes are 1.5 and solidly installed with primer and high quality glue for the PVC used. I have a Hayward super flo matrix pump. Or to a light switch and then to a breaker, that would be more of a standard installation. Hello, my motor runs for 20 seconds then stops. Or a loose base part rattling? Hi Shannon, the bolts are spinning. I have taken it apart and put it back together probably 5-6 times looking for internal issues. Well, the good news is you are at the right spot and youre definitely not alone. I dont want to assume but I am guessing the pump was just going bad, thus leaking voltage in the pool. Thanks. The arrow at the top of the hex nut points in the direction of the water flow. Something is very loose, or missing, or clamp band threads may be damaged, please be careful people have been fatally injured by pool filter tops popping off under pressure! Other causes of high pressure could be unrelated to the pump size, such as an obstruction or restriction on the return line, or a partially closed valve, or plugged wall returns, or eyeball fittings in the pool that are too small. You may need to start shopping for a new motor and shaft seal, or a whole new pump of the same size and type. Hi Rob, If the pump is the same exact model and horsepower, it sounds like either; 1). Also check that the clips and o-rings on the SS bump shaft are all in place. If so, put a damper under the pump, a piece of heavy rubber or a shim to stabilize the pump. Automatic reset is immediate after error is corrected. Hi Don, if you have four suction lines coming into the pump, that would be skimmer, skimmer, main drain and spa drain? The spider gasket as it is called, inside of the valve is not sealing the waste port like it should. I added new wire and plug end but when I plug it in it trips the breaker. If you can grab the bolt head underneath the pad with pliers, that could help, otherwise you can cut the bolts off using a reciprocating saw with a metal blade. If the amps on either reading show zero (0), then you should replace your PC Board. Pump lids are all very tight, they need to be. Davy, I just bought this pump 3-4 yrs ago? I checked impeller and seems to be spInning freely with no debris. hayward blue essence troubleshooting. Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on. Reset AquaRite Salt Chlorination Inspect Cell Light If the Inspect Cell Light is the only LED light flashing, then you can reset it by simply holding down the diagnostic button for 3 seconds, then release. It leaks from the impeler case and is noisey, so assy B is no replacement. If not, but the shaft and impeller spin freely remove the start capacitor, normally located in the motor rear, at 9 oclock, and write down the MFD number, and then order one online, or at a local electric motor repair shop. Tripping the breaker, could possibly be a bad breaker, allowing too much voltage to pass thru to the pump. Hi Davy, Your session is about to timeout due to inactivity. Hi Kathleen, sounds like a leak from the shaft seal, unless water is running out of the pump exit fitting, and running down the housing and dripping off the bottom. Please ignore my previous question I put a slight bend in the end of the wrench and was able to get a grip on the shaft , When I opened my pool the pump hummed and did not start. Both the pump motor and Polaris are wired out of the timer and the timer seems to be working correctly and I checked it by checking the voltage at the motor with the switch in the off position and then again with the switch in the on position. . I replaced my old hayward maxflow pump with the new variable speed sp2670020vsp. You can also order capacitors online. Hi John hot plug? If not, keep reading. Disconnected the chlorination device, and direct connected it eliminating that. Initially, look into the pump/strainer housing. When you see a quick spurt or spray of water when the pump shuts off, this is an area where air is entering the system, and causing priming problems. Did not raise red flags, amature lol. What is the problem with those other motors? So, grab the opening portion with pliers, while the wrench is holding the shaft still, and turn counter clockwise, it should come off, if it breaks, a new impeller is needed, but thats rare, they usually will budge. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). "dateModified": "2/24/2015",
Hi probably not related to the vacuuming, but sounds like a motor problem. Hi Jeanna, most of those slide from 230 to 115, but some do have to be unplugged and replugged. At75%, or lower, in either polarity, it's time to consider replacing the cell. Troubleshooting and diagnosing their problems. Hi, that could be many things, from low water level to a broken impeller, but its usually an air leak. "As for cleaning the pool filters, I do this every couple of days and doesn't help pressure.". Jake, sounds like you got the filter up to speed. The pump/motor, is a power flow LX, 1.5 HP, model SP151521BC, & the Sand Filter is the pro series model S210T. Fingers crossed it is not that! HI, that is usually a weak motor capacitor, which is a battery used to help the motor get up to 3450 RPM quickly. Grids not aligned properly, thus not pushed fully up into manifold },
Backwash your filter when pressure gauge rises 7-9 psi above the clean, starting pressure. HI David, did anyone empty the pump basket recently? Have a Hayward SuperPump. dhp faux leather club chair; hanna salinity tester calibration; Third, check the back of the motor, the centrifugal switch on the end of the shaft and the stationary switch at 6 oclock to be sure they are tight and aligned tab to tab, and not loose or misaligned. Ive checked out your blog and you had very good info for audience. Motors that are reversible always ship from the factory at 230V, and need to be manually switched to accept 115V. Loose wire connections or touching terminal connections cause sparking. If you havent inspected your cell yet, now is aperfect time. If the shaft is free turning, but the pump does not turn on, check power connections. Clear all debris from the heatsink (page 36) on the bottom of the drive. I connected the pump to a nearby receptacle with a heavy duty drop cord and it works fine. Hoses popping off could also indicate a high pressure problem after the filter, such as obstructed return lines, such as plugged or blocked wall returns, or closed valves. Hi Pat, yes they should be plug and play, was the cord attached already, or did you install? Let it sit overnight . I believe I have a bad capacitor. Usually the capacitor (9 oclock) or the thermal overload switch (12 oclock) must be removed to gain access to the shaft, whereupon you can use an open end wrench to grasp the shaft and turn it slightly, back and forth, to break the rust free. Hi Rick, if thats a new thing, there is probably something loose and leaking (air) when the pump shuts off. The pump then ran fine for about 10 minutes and then stopped working again. I have a thermal switch on it,thank goodness or the motor would probably be fried. Be sure though, that the motor has plenty of air flow, and the air flow vents are not blocked, and that incoming voltage is not too high or too low. What should I do? I filled the pool to the level line, but the air bubbles stayed. I have a max-flo vs pump and it cant seem to stay at a high rpm for any long stretch of time when its sunny. 3. Normally they last longer. First time pool owner (obviously dont know what we are doing). The most common places for an air leak on a pump include around the pump lid (must be really tight, with lubed o-ring), or a loose incoming water pipe bringing water (and air) into the pump. JavaScript is disabled. Try adding another inch of water. The pump need not be completely air tight, but has to pull more water than air! "@type": "ImageObject",
Likewise, check if the motor is wired correctly for the available field supply voltage. info. I tried to restart them & only got a low buzzing type noice. my hayward filter assembly on top leaks at the seam between the top (held on by six bolts) and the bottom. There must be a leak. Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. The wire size may depend on the distance of wire run. Was the filter multiport valve replumbed also? It may not display this or other websites correctly. What more can I do or will the bubbles resolve on its own? Normally though, it takes more like 15 minutes before the pump is cool enough to turn back on again, at which point you may hear a click, as the overload resets, just a second before the pump turns on again. It can also happen when voltage is incorrect (too high or too low), or when wires are shorting out, or in some cases, very hot weather and direct sunshine and other nearby sources of heat. We are a registered 501(c)3 non-profit that is funded by user donations. Replace with identical MFD number, printed on capacitor. Could also be a loose high speed wire from the switch. Is there a solution for this problem? My hayward powerflo matrix 1.5hp pump doesnt turn on after working fine the whole month of June. Manually spinning the shaft can break the rust bonds. The pump acts like it wants to pump, but doesnt. Hayward pumps come in a variety of horsepowers, voltages and speeds. Another possible cause is that the impeller is clogged with very small debris. Please contact me at mbrad39972@hotmail.com. Check the impeller and seal alignment. Hello, Capacitors are cheap to replace, or you can test the capacitor Hi when you say it shuts down, I assume you mean that the water stops flowing? So I installed a brand new Hayward W3SP2610X15 Super Pump Pool Pump, 1.5 HP last season Summer 2019 and used the electric cord from the old one which was showing its age. That is the black cylinder in the rear of the motor, located at 9 oclock. my two speed Hayword pump clicks when The Pool is a Roman 23 in ground. If not, then it will usually be a bad capacitor, or start capacitor, located at 9 oclock, in the rear, a black cylinder. It spins easily by hand and doesnt make any noise. 3 No air bubbles on my returns when not vacuuming A sticky skimmer weir door can cause water blockage to the skimmer, and give priming problems too. The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. You have both filter pump and polaris pump on one timer? Hi Doug, good question that indicates that there is an air leak coming into the pump. My EC40 bump handle doesnt feel right. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). Ours is doing the same thing.

Who Is Kelly Severide Married To In Real Life, Which Beach Is Better Sanibel Or Captiva?, Articles H

Todos os Direitos Reservados à hayward blue essence troubleshooting® 2015